ECB Measuring

The test center performs parametric and functional testing of ECB and electronic radio equipment of:

  • Digital VLSI: test systems for 512 channels, clock frequency from 50 mHz to 400 MHz, period duration from 20 ns, pulse rise time of 5 ns at the voltage of 5V;
         izmsm1                  izm 1                   izm 2                     04390 min
         Tester for VLSI digital                                     Tester for VLSI                                                 Facility for digital                             Mobile test system ТРО04390А
         parameters J750,                                              digital parameters                                              ECB measurements                                               for the influence of 
         Teradyne (the USA)                                         ETS-868                                                                                                                                 rapid temperature change
                                                                                                                                                                                                                    Temptronic installed on the board



  • digital-to-analog and analog-to-digital integral circuits: test systems for 128 channels, steepness of the rise increment 1.5 V/ns, differential and integral nonlinearity less than 0.00008% FSR, resolving capacity of voltage up to 5 mV, resolving capacity of current up to 100 nA, frequency up to 50 MHz with the accuracy of ±0,01%, influence of supply voltage/reference voltage change up to 120 dB, dynamic range up to 90 dB;
                                                                                                        ETS 780 DMT 119 min                                                                                               
                                                                                                     Stand for parametric monitoring of analog and digital
                                                                                                integral circuits and devices, DMT-119 and ETS-780 tester


  • analog integral circuits: measuring current resolution up to 1 fA, measuring voltage resolution up to 1 nV;
                                                      izm 3                          f2k
                                                           Facility for analog ECB measurements                               Digital tester for integral circuit parametric control
                                                                                                                                                                                 “FORMULA 2K”


  • communication and radio technical microwave integral circuits: frequency from 50 MHz to 20 GHz;
                                                    dmt 118 min                          sv4 min
                                                    Measuring complexes for microwave parameters                           Measuring complex for microwave parameters
                                                                        DMT-118, DMT-134



  • semiconductor devices: voltage from 1 µV to 1100 V, in DC mode from 1 pA to 100 A, in pulse mode from 1 A to 10 A;
                                                  dmt 120 min                           dmt 220 min
                                Parametric monitoring of semiconductors, diodes and stabilitrons                           Parametric monitoring of  transistors                                      
                                                                               DMT-120                                                                       DMT-220, chamber Espec SU-261



  • resistors, capacitors, chokes, transformers, resonators: frequency from 20 Hz to 3 GHz, resistance from 0.01 mOhm to 99.9999 MOhm, impedance from 3 mOhm to 500 MOhm, capacity from 0.01 fF to 9.9999 F, inductance from 0.01 nH to 99.9999 kH, Q-factor from 0.01 to 99999.9, conductivity from 300 µS to 300 S, frequency step control from 1 Hz up to GHz units, methods of GOST RV, MIL-STD;
        dmt 138 min                       dmt 137 min                       wp1 min       
            High precision LCR meter DMT-138                                            LCR meter DMT-137                                                             Workplace No. 1
                                                                                                                                                                                                 capacitor electric parameters control


       wp 2 min                      wp 3 min                       wp 4 min
                          Workplace No. 2                                                          Workplace resistor electric                                                  Coils, chokes, transformers
            capacitor electric parameters control
                                               parameters control                                                    parameters control workplaces



  • Solid-state light sources, photodiodes and devices based on them;
                                            temnajy komnata1 min                                temnajy komnata2 min
                                                                 Dark room with 2 70613                                                                Dark room with 2 electric generators, 1
                                          NS monochromators (Newport) and an optical sphere                                      oscilloscope and component power system 



  • relay;
                                                                                                        FT17R2 min
                                                                                             Measurement system for functional and parametric testing
                                                                                                 of low-current FT17 relay, LLC Sovtest ATE (Russia) 



  • modules, circuit boards and network devices;
                                                                                                       su 100 min
                                                                                                                           SU-001 control stand



  • switching devices;
  • mounting devices;
                                                                                                    gpt 815 min
                                                                                                      Voltage tester GPT-815 teraohmmeter Е6-13а

MAIN FIELDS OF ACTIVITY


member of holding